ABB

5 devices
ABB · Three-phase energy meter

A43

Core three-phase instrumentation map from ABB's documented DMTME-compatible Modbus register block.

MAP
26 points · Core instrumentation
FUNCTIONS
FC03
TRANSPORT
Modbus RTU
ABB · Three-phase energy meter

A44

Core three-phase instrumentation map from ABB's documented DMTME-compatible Modbus register block.

MAP
26 points · Core instrumentation
FUNCTIONS
FC03
TRANSPORT
Modbus RTU
ABB · Single-phase energy meter

B21

Core single-phase instrumentation map from ABB's documented DMTME-compatible Modbus register block.

MAP
7 points · Core instrumentation
FUNCTIONS
FC03
TRANSPORT
Modbus RTU
ABB · Three-phase energy meter

B23

Core three-phase instrumentation map from ABB's documented DMTME-compatible Modbus register block.

MAP
26 points · Core instrumentation
FUNCTIONS
FC03
TRANSPORT
Modbus RTU
ABB · Three-phase energy meter

B24

Core three-phase instrumentation map from ABB's documented DMTME-compatible Modbus register block.

MAP
26 points · Core instrumentation
FUNCTIONS
FC03
TRANSPORT
Modbus RTU

Eastron

7 devices
Eastron · Single-phase energy meter

SDM120-Modbus

Core FC04 measurement map for the compact single-phase SDM120-Modbus energy meter, including power, energy, frequency, power factor, and demand.

MAP
21 points · Core measurements
FUNCTIONS
FC04
TRANSPORT
Modbus RTU
Eastron · Single-phase energy meter

SDM220-Modbus

Core FC04 single-phase electrical measurement map using IEEE 754 values in normal register order.

MAP
11 points · Core measurements
FUNCTIONS
FC04
TRANSPORT
Modbus RTU
Eastron · Single-phase energy meter

SDM230-Modbus

Core FC04 measurement map for the single-phase SDM230-Modbus energy meter, covering electrical values, bidirectional energy, frequency, and demand.

MAP
20 points · Core measurements
FUNCTIONS
FC04
TRANSPORT
Modbus RTU
Eastron · Three-phase energy meter

SDM630-Modbus V2

Read-only FC04 measurement map for the three-phase SDM630-Modbus V2 energy meter, including live electrical values, demand, harmonics, and per-phase energy counters.

MAP
85 points · Extended measurements
FUNCTIONS
FC04
TRANSPORT
Modbus RTU
Eastron · Three-phase energy meter

SDM630MCT

Core FC04 three-phase electrical measurement map using IEEE 754 values in normal register order.

MAP
21 points · Core measurements
FUNCTIONS
FC04
TRANSPORT
Modbus RTU
Eastron · Three-phase energy meter

SDM72CT-M

Core FC04 three-phase electrical measurement map using IEEE 754 values in normal register order.

MAP
21 points · Core measurements
FUNCTIONS
FC04
TRANSPORT
Modbus RTU
Eastron · Three-phase energy meter

SDM72D-M

Core FC04 three-phase electrical measurement map using IEEE 754 values in normal register order.

MAP
21 points · Core measurements
FUNCTIONS
FC04
TRANSPORT
Modbus RTU